EIB 1500

    Specifications

    Specifications

    EIB 1512

    EIB 1592 F

    EIB 1592 M

    Input

    Interface

    1 VPP (encoder with distance-coded reference marks)

    Input frequency

    ≤ 400 kHz

    Electrical connection

    2 x M23 flange connector (female), 12 pin

    Power supply for encoders

    DC 5 V ± 0.25 V (generated from power supply for EIB); ≤ 150 mA per encoder

    Cable length

    ≤ 6 m

    Output

    Interface

    EnDat 2.2

    Fanuc Serial Interface

    Mitsubishi high speed interface

    Ordering designation

    EnDat 22

    Fanuc 02

    Mit 02-4

    Calculation time tcal

    Clock frequency

    ≤ 5 µs

    ≤ 16 MHz

    Electrical connection

    8-pin M12 flange socket (male)

    Cable length1) (with HEIDENHAIN cable)

    ≤ 100 m

    ≤ 20 m

    ≤ 20 m

    Subdivision

    ≤ 16 384-fold (depending on the encoder)

    Voltage supply

    3.6 V to 14 V DC

    Power consumption (max.)

    3.6 V: < 3.3 W

    14 V: < 3.0 W (including current consumption of the scanning heads (IMmax = 150 mA)

    Current consumption (typical, without load)

    5 V: 130 mA + 1.4 x 2 x IMtyp

    Operating temperature

    Storage temperature

    0 °C to 70 °C

    –30 °C to 70 °C

    Vibration 55 to 2 000 Hz

    Shock 11 ms

    100 m/s2 (EN 60 068-2-6)

    300 m/s2 (EN 60 068-2-27)

    Protection

    IP 65

    Weight

    ≈ 0.3 kg

    1) Because of the high power consumption (EIB + 2 encoders), the influence of the cable length (voltage drop) must be tested in detail