Specifications
EIB 5281
EIB 5211
EIB 5181
Functional safety
Determined by the connected encoder and subsequent electronics (including their configuration); the EIB has no effect on the safe position
Encoder input
Interface
EnDat 2.1
EnDat 2.2
1 VPP/EnDat 2.1/EnDat 2.2
Ordering designation
EnDat01/EnDat02
EnDat229)
EnDat01/EnDat02/EnDat22
Electrical connection
17-pin M23 flange socket (female) with coupling ring
12-pin M12 flange socket
25-pin D-sub connector (female)
Voltage supply of encoder
The EIB passes the supply voltage from the subsequent electronics to the connected encoder
Cable length1)
< 6 m
< 100 m
Temperature sensor input
Quantity
3
Connectable sensors2)
KTY 84-130, PT 1000, PTC, PTC triplet3)
Evaluation accuracy tolerance
Typically: ±1 K; maximum: ±2 K
Time constant for temperature measurement
Please indicate when ordering
Set using DIP switches
7-pin M17 flange socket (female)
6-pin header (male)
Cable length4)
< 20 m
Control output
EnDat22
17-pin M23 flange socket (male)
8-pin M12 flange socket
25-pin D-sub connector (male)
< 50 m
< 3 m
Supply voltage
5 V ±10 %5)
3.6 V ... 14 V
Power consumption6)
Typical: 200 mW; max. 300 mW
Typical: 160 mW; max. 210 mW
Typical: 250 mW; max. 350 mW
Temperature output
Emulation of PT 1000 behavior7)
–
Emulation of PT 1000 or KTY84-130 behavior7)
Emulation accuracy tolerance8)
Typically: ±3 K; maximum: ±4 K
Operating temperature
0 °C to 70 °C
Storage temperature
–30 °C to 70 °C
Vibration 55 Hz to 2000 Hz
Shock 11 ms
100 m/s2 (EN 60068-2-6)
300 m/s2 (EN 60068-2-27)
10 m/s2 (EN 60068-2-6)
30 m/s2 (EN 60068-2-27)
Protection EN 60529
IP65 (when engaged)
IP20
Altitude
< 2000 m above sea level
Mass
0.5 kg
1) Applies only to HEIDENHAIN cables; be sure to consider the voltage drop
2) For further information, please refer to Temperature evaluation and Monitoring functions
3) Please select when ordering; EIB 5181 is configured using DIP switches
4) Observe the information from the motor manufacturer
5) Take the supply voltage range of the encoder into account
6) Without power or current consumption of the encoder; version with switching output: additional power consumption of 50 mW
7) See Emulation of PT 1000 behavior
8) Applies to cable lengths < 1 m
9) The encoder must be designed for connection to the EIB 5211
EIB 5000 - Sensor Boxes for Temperature Measurement of Direct Drive Motors