Incremental
Specifications
LS 388 C
LS 328 C
Measuring standard
Glass scale with DIADUR graduation
Accuracy grade
± 10 µm
Measuring length ML*
70, 120, 170, 220, 270, 320, 370, 420, 470, 520, 570, 620,
670, 720, 770, 820, 870, 920, 970, 1020, 1140, 1240
Incremental signals
1 VPP
TTL
Grating period
20 µm
Edge separation a
–
≤ 5 µs
Reference mark
Distance-coded
Recommended measuring step1)
10 µm, 5 µm
Power supply
5 V DC ± 5 %/< 100 mA (without load)
Electrical connection
Separate adapter cable connectable to mounting block
Cable length
≤ 30 m (with HEIDENHAIN cable)
Traversing speed
≤ 60 m/min
Required moving force
≤ 5 N
Vibration 55 Hz to 2 000 Hz
Shock 6 ms
≤ 150 m/s2 (EN 60 068-2-6)
≤ 300 m/s2 (EN 60 068-2-27)
Operating temperature
0 °C to 50 °C
Protection EN 60 529
IP 53 when mounted according to the instructions
Weight
0.27 kg + 0.67 kg/m ML
* Please select when ordering
1) For position measurement
Digital Readouts / Linear Encoders for Manually Operated Machine Tools
CAD
Mounting Instruction